Rack PDU 2G, Metered-by-Outlet, ZeroU, 11.0kW, 230V, (21) C13 & (3) C19
Enter ZIP code to see pricing
1-Year Secure Network Management Card subscription included
Ideal for high density server and networking applications
Real-time remote monitoring of connected load through EcoStruxure IT and other platforms
Environmental Data
APC NetShelter Metered-by-Outlet Rack PDUs
1-Year Secure Network Management Card subscription included
Ideal for high density server and networking applications
Real-time remote monitoring of connected load through EcoStruxure IT and other platforms
Extensive list of compatible products and accessories
Stay on top by defining alarm thresholds in order to avoid overloaded circuits
APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection Current metering provides real-time remote monitoring of connected loads Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency
Overview
Presentation
APC Metered by Outlet Rack Power Distribution Units (PDUs) provide individual outlet power metering to enable energy optimization and circuit protection. Current metering provides real-time remote monitoring of connected loads. Metered by Outlet Rack PDUs provide power utilization data to allow Data Center Managers to make informed decisions on load balancing and right sizing IT environments to lower total cost of ownership. Metered by Outlet Rack PDUs include real power monitoring, a temperature/humidity sensor port, locking IEC receptacles, and ultra low profile circuit breakers. Users can access and configure Metered by Outlet Rack PDUs through secure Web, SNMP, or Telnet Interfaces which are complimented by APC Centralized Management platforms using InfraStruxure Central, Operations, Capacity, and Energy Efficiency.
Main
Product or Component Type
PDU
Main Input Voltage
400 V 3 phase
Input current limits
16 A
Input Frequency
50/60 Hz
Main Output Voltage
230 V
Input Connection Type
Number of power socket outlets
Load Capacity
11000 VA
Line Rated Current
16 A
Max current draw
16 A
Max line current
16 A
PDU Type
Metered outlet
Number of rack unit
0U
Number of cables
1
Cable length
5.9 ft (1.8 m)
Provided Equipment
Environmental footprint
Total lifecycle Carbon footprint
3 216 kg CO2 eq.
Carbon footprint of the manufacturing phase [A1 to A3]
188 kg CO2 eq.
Carbon footprint of the distribution phase [A4]
1 kg CO2 eq.
Carbon footprint of the installation phase [A5]
0.1 kg CO2 eq.
Carbon footprint of the use phase [B2, B3, B4, B6]
3 021 kg CO2 eq.
Carbon footprint of the end-of-life phase [C1 to C4]
5 kg CO2 eq.
Use Better
Materials and Substances
Average percentage of recycled plastic content
15 %
Packaging made with recycled cardboard
Yes
Packaging without single use plastic
Yes
SCIP Number
1cdb2fed-a06f-4574-913d-8df8e70936b2
EU RoHS Directive
Compliant By ExemptionREACh Regulation
Free of Substances of Very High Concern above the thresholdHalogen content performance
Product contains halogen above thresholds
Use Longer
Lifetime extension
Repair
No
Use Again
Repack and remanufacture
Circularity Profile
End of Life InformationRemovable battery
Yes
Take-back
No
WEEE Label
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins.
2 Results